VARALKA Heat Exchangers

Experience the excellence of our VARALKA Heat Exchangers, meticulously designed by a top-rated exporter, supplier, and trader with over 29 years of spectacular expertise in the industry. Offering a diverse range of superior products including Welded Plate Heat Exchangers, Air and Oil Coolers Heat Exchangers, Hygienic Plate Heat Exchangers, Laser Welded Plate Heat Exchangers, and Gasketed Plate Heat Exchangers, we guarantee immaculate performance for a versatile range of applications. Renowned for their unmatched energy efficiency, compact design, robust construction, low maintenance, and outstanding heat transfer capabilities, VARALKA Heat Exchangers ensure a level of reliability that surpasses most competitors. Our commitment to delivering the best price without compromising on quality has positioned us as the preferred choice when compared to other suppliers offering similar products at the lowest price in the market. With supply ability across All India, VARALKA Heat Exchangers are celebrated for their durability, user-friendly operation, and cutting-edge engineering, making them the optimal solution for all your industrial cooling and heating needs.

Gasketed Plate Heat Exchanger

MOQ : 1 Unit

  • Condition
  • New
  • Diameter
  • Connection diameters range from 25 mm to 300 mm
  • Dimensions
  • Varies with model, typical range from 400 mm x 100 mm x 150 mm to 2500 mm x 800 mm x 300 mm
  • Liquid Flow Rate
  • Up to 360 m3/h, depending on model and application
  • Max Pressure
  • Up to 25 bar
  • Max. Capacity
  • Varies by model, up to 3 MW heat transfer
  • Number of Pipe
  • 4 main process ports (2 inlets, 2 outlets)
  • Power
  • Not applicable (no direct power consumption, passive unit)
  • Structure
  • Other, Gasketed plate type, modular assembly
  • Temperature
  • Other, Suitable for temperatures up to 180C
  • Thickness
  • Plate thickness typically ranges from 0.5 mm to 0.8 mm
  • Weight
  • Varies with size and model, typically from 10 kg to over 1000 kg
  • Working Presssure
  • Up to 25 bar, depending on model

Hygienic Plate Heat Exchangers

MOQ : 1 Unit

  • Condition
  • New
  • Diameter
  • No round diameter (rectangular plate design)
  • Dimensions
  • Customizable as required
  • Liquid Flow Rate
  • Up to 100 m3/h (model dependent)
  • Max Pressure
  • Up to 10 bar
  • Max. Capacity
  • Up to 250,000 kcal/hr or as per design
  • Number of Pipe
  • Multiple inlets/outlets depending on model
  • Power
  • No power required (external pump needed)
  • Structure
  • Other, Frame and Plate Compact Construction
  • Temperature
  • Other, -10C to 180C
  • Thickness
  • Plate thickness typically 0.5 to 1.0 mm
  • Weight
  • Varies as per model
  • Working Presssure
  • Up to 10 bar

Laser Welded Plate Heat Exchangers

MOQ : 1 Unit

  • Condition
  • New
  • Diameter
  • Connection ports from DN32 to DN300
  • Dimensions
  • Custom sizes available; example: 1000 x 600 x 2000 mm (LxWxH)
  • Liquid Flow Rate
  • Up to 3000 m3/h depending on model
  • Max Pressure
  • Up to 25 bar
  • Max. Capacity
  • Up to 10 MW (thermal duty)
  • Power
  • Not applicable (passive heat exchanger)
  • Structure
  • Other, Laser welded plates, frame with tightening bolts
  • Temperature
  • Other, -20C to +200C
  • Thickness
  • Plates typically 0.5 mm to 1.2 mm thickness
  • Voltage
  • Not applicable (no electrical requirement)
  • Weight
  • Depends on specific model, typically ranges from 200 kg to 3000 kg
  • Working Presssure
  • Up to 25 bar

Welded Plate Heat Exchangers

MOQ : 1 Unit

  • Air Volume
  • Not applicable (for liquids/gases)
  • Condition
  • New
  • Diameter
  • Custom, based on inlet/outlet size
  • Dimensions
  • Custom; typically ranges from 800 mm x 600 mm x 1000 mm and above
  • Liquid Flow Rate
  • Up to 2000 m3/h (design-dependent)
  • Max Pressure
  • Up to 100 bar
  • Max. Capacity
  • Up to 50 MW (thermal)
  • Number of Pipe
  • Custom, based on application
  • Power
  • Not applicable (passive device)
  • Structure
  • Other, Welded Plate Construction
  • Temperature
  • Other, -50C to +400C
  • Thickness
  • Plates typically 0.6 - 1.2 mm
  • Voltage
  • Not applicable (passive device)
  • Weight
  • Variable as per design, typically 100 kg to several tons
  • Working Presssure
  • Up to 100 bar

Air and Oil Coolers Heat Exchangers

MOQ : 1 Unit

  • Air Volume
  • 1200 - 3800 m3/h
  • Condition
  • New
  • Diameter
  • Fan Diameter: 280-400 mm
  • Dimensions
  • 500 x 200 x 480 mm (standard)
  • Liquid Flow Rate
  • 20 - 100 L/min
  • Max Pressure
  • 16 bar
  • Max. Capacity
  • 50,000 kcal/h
  • Number of Pipe
  • 18-32 tubes, model dependent
  • Power
  • 0.18 - 1.5 kW
  • Structure
  • Other, Finned tube type, compact frame with mounting legs
  • Temperature
  • Other, Up to 120C
  • Thickness
  • Core thickness: 52 mm
  • Voltage
  • 220V/380V/415V
  • Weight
  • Approx. 15-40 kg (varies by model)
  • Working Presssure
  • Up to 16 bar

Offline Cooling Systems

MOQ : 1 Unit

  • Air Volume
  • 1600 m3/h
  • Condition
  • New
  • Diameter
  • 32 mm (inlet/outlet)
  • Dimensions
  • 450 x 320 x 300 mm
  • Liquid Flow Rate
  • 50 L/min
  • Max Pressure
  • 20 bar
  • Max. Capacity
  • 15 kW
  • Power
  • 0.55 kW
  • Structure
  • Other, Compact Fin-and-Tube
  • Temperature
  • Other, -10C to 120C
  • Thickness
  • 60 mm
  • Voltage
  • 220V / 380V
  • Weight
  • 18 kg
  • Working Presssure
  • 16 bar

Drain Line Oil Coolers

MOQ : 1 Unit

  • Air Volume
  • Up to 2000 m3/hr
  • Condition
  • New
  • Diameter
  • Fan Diameter: 200-300 mm
  • Dimensions
  • Varies, Typical: 320x320x100 mm
  • Liquid Flow Rate
  • 10-100 L/min
  • Max Pressure
  • 16 bar
  • Max. Capacity
  • Up to 30 kW
  • Number of Pipe
  • 1-2 (varies by size/model)
  • Power
  • 60W - 250W
  • Structure
  • Other, Finned Tube Construction with Electric Fan
  • Temperature
  • Other, -10C to 120C
  • Thickness
  • 35-50 mm
  • Voltage
  • 230V AC / 24V DC
  • Weight
  • Approx. 7-15 kg depending on model
  • Working Presssure
  • Max. 16 bar


Back to top